Channel Pumps
type: productmeta.slug/products/alfa-laval-sru

Alfa Laval SRU Rotary Lobe Pump

↑ meta.title

Facetsentities.csv

Metadata

type: product
slug: /products/alfa-laval-sru
metaTitle: Alfa Laval SRU Rotary Lobe Pump
title: Alfa Laval SRU Rotary Lobe Pump
navTitle: Alfa Laval SRU
metaDescription: The Alfa Laval SRU rotary lobe pump gently transfers viscous, shear-sensitive fluids to 106 m³/h across food, dairy, pharmaceutical and chemical duties.

Content blocks

content.intro

The Alfa Laval SRU is a hygienic rotary lobe pump: a positive displacement pump built for gentle, low-shear, low-pulsation transfer of viscous and shear-sensitive fluids. It suits demanding hygienic duties in food, dairy, pharmaceutical and chemical processing, and handles flows up to 106 m³/h. Channel Pumps supplies and sizes the SRU to your duty.

content.heroimage slotasset: sru-primary.png
Alfa Laval SRU hygienic rotary lobe pump

alt: Alfa Laval SRU hygienic rotary lobe pump

content.gallery
content.gallery.heading

The SRU rotary lobe pump range

content.gallery.images[]1 item
content.gallery.images[0]image slotasset: sru-range.png
The Alfa Laval SRU range of hygienic rotary lobe pumps

alt: The Alfa Laval SRU range of hygienic rotary lobe pumps

content.key_features[]5 items
content.key_features[0]
content.key_features[0].title

Gentle, low-shear handling

content.key_features[0].description

Protects product quality when moving shear-sensitive fluids.

content.key_features[1]
content.key_features[1].title

Consistent, low-pulsation flow

content.key_features[1].description

Steady delivery that supports process uptime.

content.key_features[2]
content.key_features[2].title

Hygienic design

content.key_features[2].description

Supports validated cleaning, for product safety.

content.key_features[3]
content.key_features[3].title

Process flexibility

content.key_features[3].description

Handles a range of viscosities and products on one pump platform.

content.key_features[4]
content.key_features[4].title

Low-maintenance build

content.key_features[4].description

Robust gearbox, heavy-duty shafts, torque-locking assemblies and taper roller bearings.

content.body

The SRU is Alfa Laval's hygienic rotary lobe pump: a positive displacement design for processes where product quality matters as much as throughput. Its low-shear, low-pulsation action moves viscous and shear-sensitive fluids gently, so it fits food, dairy, beverage, home and personal care, biotechnology and pharmaceutical duties. Channel Pumps supplies the SRU and sizes it to your duty point. We match the pump head, connections and configuration to your flow, differential pressure, medium and hygiene requirement.

content.how_it_works

A rotary lobe pump moves fluid by positive displacement. Two high-precision rotors turn in mesh inside the pump head, carrying fluid around the casing from inlet to outlet in a gentle, low-pulsation action. Because the fluid isn't forced through a tight clearance at speed, shear stays low. That is what protects delicate products. The SRU adds a front cover seal with defined compression, a rotor nut retention design, and a drainable pump head to support cleaning. It is built to 3-A Sanitary and FDA hygienic standards, and is available to ATEX requirements for explosive atmospheres.

content.specifications[]5 items
content.specifications[0]
content.specifications[0].label

Flow rate

content.specifications[0].value

up to 106 m³/h

content.specifications[0].note

range maximum

content.specifications[1]
content.specifications[1].label

Differential pressure

content.specifications[1].value

up to 20 bar

content.specifications[1].note

range maximum

content.specifications[2]
content.specifications[2].label

Temperature

content.specifications[2].value

up to 200 °C

content.specifications[3]
content.specifications[3].label

Pump head displacements

content.specifications[3].value

12 options

content.specifications[4]
content.specifications[4].label

Hygienic standards

content.specifications[4].value

3-A Sanitary and FDA; available to ATEX for hazardous areas

content.quote_cta

Channel Pumps sizes and supplies the SRU for your process. Tell us your flow, differential pressure, medium and its viscosity, temperature, and any hygiene or hazardous-area requirement, and we'll specify the right pump head and configuration. Request a quote.

content.documents[]3 items
content.documents[0]documenttype: leaflet
SRU rotary lobe pump — product leaflet

sru-product-leaflet.pdf

Alfa Laval's SRU leaflet: range overview, features and specification data.

content.documents[1]documenttype: manual
SRU range — instruction manual

sru-instruction-manual.pdf

Installation, operation and maintenance manual for the SRU range.

content.documents[2]documenttype: manual
SRU instruction manual — ATEX addendum

sru-atex-addendum.pdf

Addendum covering SRU use in potentially explosive (ATEX) atmospheres.

content.related_products
content.related_products.heading

Other rotary lobe pumps

content.related_products.source

autogenerated:query

content.related_products.query
content.related_products.query.cluster

rotary-lobe-pump

content.related_products.query.limit4
content.related_products.query.order

priority

content.faq[]5 items
content.faq[0]
content.faq[0].question

What is the Alfa Laval SRU used for?

content.faq[0].answer

The SRU is a hygienic rotary lobe pump for gentle, low-shear transfer of viscous and shear-sensitive fluids. It's used in food, dairy, beverage, home and personal care, biotechnology and pharmaceutical processing.

content.faq[1]
content.faq[1].question

What flow and pressure can the SRU handle?

content.faq[1].answer

The SRU handles flows up to 106 m³/h and differential pressure up to 20 bar, with 12 pump head displacements to match a duty. Confirm your configuration with Channel Pumps.

content.faq[2]
content.faq[2].question

Does the SRU meet hygienic standards?

content.faq[2].answer

The SRU is built to 3-A Sanitary and FDA hygienic standards, with a drainable pump head that supports validated cleaning.

content.faq[3]
content.faq[3].question

Is the SRU available for hazardous areas?

content.faq[3].answer

Yes — the SRU is available to ATEX requirements for explosive atmospheres. Specify your zone and the medium when you enquire.

content.faq[4]
content.faq[4].question

Can Channel Pumps size an SRU for my duty?

content.faq[4].answer

Yes. Channel Pumps sizes and supplies the SRU — give us your flow, pressure, medium and any hygiene or hazard requirement, and we'll specify the configuration.

content.citations[]1 item
content.citations[0]
content.citations[0].source

Alfa Laval — SRU rotary lobe pump

content.citations[0].url

https://www.alfalaval.co.uk/products/fluid-handling/pumps/rotary-lobe-pumps/sru/